- Title
- Gd L3 edge XAS transmission and XAS fluorescence of Gd standards for studies of hydrothermal fluids and rare metals deposits
- DOI
- 10.26302/SSHADE/EXPERIMENT_JB_20182211_002
- Data reference
- Louvel, Marion; Etschmann, Barbara; Brugger, Joel (2018): Gd L3 edge XAS transmission and XAS fluorescence of Gd standards for studies of hydrothermal fluids and rare metals deposits. SSHADE/FAME (OSUG Data Center). Dataset/Spectral Data. https://doi.org/10.26302/SSHADE/EXPERIMENT_JB_20182211_002
- Publications
- Database(s)
- Experimentalists
- Type(s)
- laboratory measurement
- Description
- REE transport in alkaline fluids at high P-T
- Number of spectra
- 2
- Comments
- These data were acquired on the BM30 beamline in the frame of the 30-02-1139 proposal.
- Variable type(s)
-
- observation mode
- sample composition
- Instrument
- X-ray Absorption Spectroscopy measured in transmission mode
- Sample holder
- simple holder
- Standard medium
- unknown
- Observation mode
- spectrum
- Spectral range type(s)
- hard X
- Valid spectral range(s)
-
Min - Max () Sampling () Resolution () Position accuracy () Absorption edge #1 7100.0 - 7880.0 0.371 (L3: 7.2428 ) - Comments
- The resolution in the above table is the resolution given by the monochromator. The energy was calibrated by measuring the absorption edge of a reference: Cu metallic foil (first maximum of the derivative set at 8979 eV).
Definition: incidence and emergence angles are positive with origin at nadir. Emergence angle in transmission is larger than 90° (=180°-i).
- Observation geometry
- direct
- Observation mode
- fixed angles
- Observation mode
- averaged
- Instrument
- X-ray Absorption Spectroscopy measured in fluorescence mode
- Sample holder
- Institut Néel autoclave, see Testemale et al., Rev. Sci. Instrum., 2005.
- Standard medium
- unknown
- Observation mode
- spectrum
- Spectral range type(s)
- hard X
- Valid spectral range(s)
-
Min - Max () Sampling () Resolution () Position accuracy () Absorption edge #1 7100.0 - 7880.0 0.371 (L3: 7.2428 ) - Comments
- The resolution in the above table is the resolution given by the monochromator. The energy was calibrated by measuring the absorption edge of a reference: Cu metallic foil (first maximum of the derivative set at 8979 eV).
Definition: emergence angle is positive with origin at nadir. Azimuth origin (increasing clockwise) is arbitrary.
- Observation geometry
- directional
- Observation mode
- fixed angles
- Comments
- Emitted x-rays are collected in a solid angle directed at 90 degrees from the incident beam.
- Observation mode
- averaged
- Date begin - end
- 2018-11-21 - 2018-11-24
Versions
- Release date
- 2025-04-23 14:23:41+0000 UTC
- Version (Date)