- DOI
- 10.26302/SSHADE/EXPERIMENT_JC_20220615_001
- Data reference
- Couturier, Julien; Lallemand, Claire; Levard, Clément; Chaurand, Perrine; Rose, Jérôme; Collin, Blanche (2022): Y K edge XAS transmission and XAS fluorescence of Yttrium components at 20K. SSHADE/FAME (OSUG Data Center). Dataset/Spectral Data. https://doi.org/10.26302/SSHADE/EXPERIMENT_JC_20220615_001
- Publications
- Database(s)
- Experimentalists
- Type(s)
- laboratory measurement
- Description
- Determination of the yttrium speciation variability in bauxite residues of various origin, age and storage conditions
- Number of spectra
- 13
- Comments
- These data were acquired on the BM30 beamline in the frame of the EV-471 proposal.
- Variable type(s)
-
- observation mode
- sample composition
- Instrument
- X-ray Absorption Spectroscopy measured in transmission mode
- Sample holder
- simple holder
- Standard medium
- unknown
- Observation mode
- spectrum
- Spectral range type(s)
- hard X
- Valid spectral range(s)
-
Min - Max ($eV$) Sampling ($eV$) Resolution ($eV$) Position accuracy ($eV$) Absorption edge #1 16850.0 - 18000.0 0.874 $Y$ (K: 17.0384 $keV$) - Comments
- The resolution in the above table is the resolution given by the monochromator. The energy was calibrated by measuring the absorption edge of a reference: Y metallic foil (first maximum of the derivative set at 17038 eV).
Definition: incidence and emergence angles are positive with origin at nadir. Emergence angle in transmission is larger than 90° (=180°-i).
- Observation geometry
- direct
- Observation mode
- fixed angles
- Observation mode
- averaged
- Instrument
- X-ray Absorption Spectroscopy measured in fluorescence mode
- Sample holder
- ESRF helium mini-cryostat
- Standard medium
- unknown
- Observation mode
- spectrum
- Spectral range type(s)
- hard X
- Valid spectral range(s)
-
Min - Max ($eV$) Sampling ($eV$) Resolution ($eV$) Position accuracy ($eV$) Absorption edge #1 16850.0 - 17580.0 0.874 $Y$ (K: 17.0384 $keV$) - Comments
- The resolution in the above table is the resolution given by the monochromator. The energy was calibrated by measuring the absorption edge of a reference: Y metallic foil (first maximum of the derivative set at 17038 eV).
Definition: emergence angle is positive with origin at nadir. Azimuth origin (increasing clockwise) is arbitrary.
- Observation geometry
- directional
- Observation mode
- fixed angles
- Comments
- Emitted x-rays are collected in a solid angle directed at 90 degrees from the incident beam.
- Observation mode
- averaged
- Date begin - end
- 2022-06-15 - 2022-06-20
Versions
- Release date
- 2023-11-10 10:52:59 UTC+0000
- Version (Date)
- #1 (2023-11-10 10:52:59 UTC+0000, Updated: 2024-06-11 14:05:48 UTC+0000)