Experiment
Title
NIR-MIR reflectance spectra (i=0°, e=30°, az=0°) of phyllosilicates and Phobos simulants (mixed silicates and coals)
DOI
10.26302/SSHADE/EXPERIMENT_OP_20240717_001
Data reference
Wargnier, Antonin; Poch, Olivier; Beck, Pierre (2022): NIR-MIR reflectance spectra (i=0°, e=30°, az=0°) of phyllosilicates and Phobos simulants (mixed silicates and coals). SSHADE/GhoSST (OSUG Data Center). Dataset/Spectral Data. https://doi.org/10.26302/SSHADE/EXPERIMENT_OP_20240717_001
Publications
Type(s)
laboratory measurement
Description
MIR (1.2-19.9 µm) reflectance spectra (i=0°, e=30°, az=0°) acquired with a biconical reflectance kit on a FTIR instrument of several mixtures and endmembers used as Phobos simulants
Number of spectra
15
Variable type(s)
  • sample composition
Instrument
Brucker Vertex 70 – transmission Mid-IR
Sample holder
Aluminum sample holder in a biconical reflectance kit A513/QA
Standard medium
air
Observation mode
spectrum
Spectral range type(s)
NIR, MIR
Valid spectral range(s)
Min - Max (${\mu}m$) Sampling (${\mu}m$) Resolution (${\mu}m$) Position accuracy (${\mu}m$) Absorption edge
#1 1.5 - 18.0
Observation geometry
biconical
Observation mode
fixed angles
Incidence angle
0.0°
Emergence angle
30.0°
Azimuth angle
0.0°
Phase angle
30.0°
Resolution observation
5.0°
Illumination
Observation
Comments
some wavelength dependent polarization
Observation mode
single spot
Spatial resolution
5.0 ${\pm}$ 1.0 $mm$
Date begin
2022-01-01

Versions

Release date
2024-07-17 14:48:51 UTC+0000
Version (Date)
#1 (2024-07-17 14:48:51 UTC+0000, Updated: 2024-07-17 14:48:51 UTC+0000)
Sponsors
  • Centre National d’Etudes Spatiales (CNES) (Scientific support of the MIRS instrument onboard the MMX mission)