- DOI
- 10.26302/SSHADE/EXPERIMENT_PC_20180420_001
- Data reference
- Chaurand, Perrine; Collin, Blanche (2017): Ce L3 edge XAS HERFD of mouse lung exposed to CeO2 nanoparticles at 10K. SSHADE/FAME (OSUG Data Center). Dataset/Spectral Data. https://doi.org/10.26302/SSHADE/EXPERIMENT_PC_20180420_001
- Publications
- Database(s)
- Experimentalists
- Type(s)
- laboratory measurement
- Number of spectra
- 1
- Variable type(s)
-
- no
- Standard medium
- unknown
- Observation mode
- spectrum
- Spectral range type(s)
- hard X
- Valid spectral range(s)
-
Min - Max ($eV$) Sampling ($eV$) Resolution ($eV$) Position accuracy ($eV$) Absorption edge #1 5650.0 - 6000.0 0.3 $Ce$ (K: 40.443 $keV$) - Comments
- The resolution in the above table is the resolution given by the monochromator. The energy was calibrated by measuring the K spectrum of a reference Cr metallic foil (first maximum of the derivative set at 5989 eV).
- Observation mode
- single spot
- Date begin
- 2017-02-05
Versions
- Release date
- 2018-06-05 08:38:16 UTC+0000
- Version (Date)
- #1 (2018-06-05 08:38:16 UTC+0000, Updated: 2018-11-20 14:23:23 UTC+0000)