Spectrum

MIR ATR spectrum of Cs-exchanged beidellite (SbId-1) under 70% relative humidity of D2O vapor

Title
MIR ATR spectrum of Cs-exchanged beidellite (SbId-1) under 70% relative humidity of D2O vapor
DOI
10.26302/SSHADE/EXPERIMENT_AK_20141114_1
Data reference
Kuligiewicz, Artur; Derkowski, Arkadiusz; Gionis, Vassilis; Chryssikos, Georgios (2014): Mid-infrared attenuated total reflectance experiment with Cs+ exchanged less 0.1 μm size fraction of beidellite (SbId-1) equilibrated with D2O vapor under variable relative humidity. SSHADE/LSD (OSUG Data Center). Dataset/Spectral Data. https://doi.org/10.26302/SSHADE/EXPERIMENT_AK_20141114_1
Publications
Experiment type
laboratory measurement
Type
corrected ATR absorbance
Intensity unit
AU
Instrument
FTIR-ATR-MIR
Sample holder
The ATR plate fitted with a home-made envrionmental chamber at room p,T
Standard medium
vacuum
Observation mode
spectrum
Spectral range type(s)
MIR
Valid spectral range(s)
Min - Max ($cm^{-1}$) Sampling ($cm^{-1}$) Resolution ($cm^{-1}$) Position accuracy ($cm^{-1}$) Absorption edge
#1 450.0 - 4500.0 1.0 4.0
Scan number
100
Observation geometry
specular
Observation mode
fixed angles
Incidence angle
45.0°
Emergence angle
45.0°
Observation mode
single spot
Experiment
Mid-infrared attenuated total reflectance experiment with Cs+ exchanged less 0.1 μm size fraction of beidellite (SbId-1) equilibrated with D2O vapor under variable relative humidity
Date begin
2014-11-14
Release date
2019-07-30 07:35:50 UTC+0000
Version (Date)
#2 (2019-07-30 07:35:50 UTC+0000)
History
Date Mode Version Status Comments
2017-09-08 14:45:50 UTC+0000 first import #1 obsolete version New MIR ATR spectrum of Cs-SbId-1 smectite
2019-07-30 07:35:50 UTC+0000 new version #2 valid version New MIR ATR spectrum of Cs-SbId-1 smectite
Analysis
Removal of atmospheric lines
Quality flag
4
Validator(s)