Fe K edge XAS fluorescence of iron ferrous solution (Fe2+ 0.045m, HCl 0.1m, Na 0.356m, Cl 0.547m) at 500bar and 300°C
- Title
- Fe K edge XAS fluorescence of iron ferrous solution (Fe2+ 0.045m, HCl 0.1m, Na 0.356m, Cl 0.547m) at 500bar and 300°C
- DOI
- 10.26302/SSHADE/EXPERIMENT_DT_20161207_001
- Data reference
- Testemale, Denis (2006): Fe K edge XAS fluorescence of iron ferrous solution in hydrothermal conditions at 500bars and between 25 and 450°C. SSHADE/FAME (OSUG Data Center). Dataset/Spectral Data. https://doi.org/10.26302/SSHADE/EXPERIMENT_DT_20161207_001
- Publications
- Database
- Experimentalists
- Experiment type
- laboratory measurement
- Type
- fluorescence emission
- Intensity unit
- AU
- Instrument
- X-ray Absorption Spectroscopy measured in fluorescence mode
- Sample holder
- Institut Néel autoclave, see Testemale et al., Rev. Sci. Instrum., 2005.
- Standard medium
- unknown
- Observation mode
- spectrum
- Spectral range type(s)
- hard X
- Excitation wavelength
- hard X
- Valid spectral range(s)
-
Min - Max ($eV$) Sampling ($eV$) Resolution ($eV$) Position accuracy ($eV$) Absorption edge #1 6999.97 - 7963.42 0.36 $Fe$ (K: 7.112 $keV$) - Comments
- The resolution in the above table is the resolution given by the monochromator. The energy was calibrated by regularly measuring the spectrum of a reference metallic foil (first maximum of the derivative set at 7112 eV).
- Observation mode
- single spot
- Experiment
- Fe K edge XAS fluorescence of iron ferrous solution in hydrothermal conditions at 500bars and between 25 and 450°C
- Date begin
- 2006-05-07
- Release date
- 2018-01-31 23:51:01 UTC+0000
- Version (Date)
- #1 (2018-01-31 23:51:01 UTC+0000, Updated: 2017-07-12 11:31:16 UTC+0000)
- History
-
Date Mode Version Status Comments 2017-07-04 15:51:00 UTC+0000 first import #1 valid version First import
- Analysis
- raw averaged spectra
- Quality flag
- 5