Spectrum

Fe K edge XAS fluorescence of iron ferrous solution (0.075m, HCl 0.1m, Li 11.825m, Cl 12.031m) at 500bar and 100°C

Title
Fe K edge XAS fluorescence of iron ferrous solution (0.075m, HCl 0.1m, Li 11.825m, Cl 12.031m) at 500bar and 100°C
DOI
10.26302/SSHADE/EXPERIMENT_DT_20161207_001
Data reference
Testemale, Denis (2006): Fe K edge XAS fluorescence of iron ferrous solution in hydrothermal conditions at 500bars and between 25 and 450°C. SSHADE/FAME (OSUG Data Center). Dataset/Spectral Data. https://doi.org/10.26302/SSHADE/EXPERIMENT_DT_20161207_001
Publications
Database
Experimentalists
Experiment type
laboratory measurement
Type
fluorescence emission
Intensity unit
AU
Instrument
X-ray Absorption Spectroscopy measured in fluorescence mode
Sample holder
Institut Néel autoclave, see Testemale et al., Rev. Sci. Instrum., 2005.
Standard medium
unknown
Observation mode
spectrum
Spectral range type(s)
hard X
Excitation wavelength
hard X
Valid spectral range(s)
Min - Max ($eV$) Sampling ($eV$) Resolution ($eV$) Position accuracy ($eV$) Absorption edge
#1 6999.97 - 7963.42 0.36 $Fe$ (K: 7.112 $keV$)
Comments
The resolution in the above table is the resolution given by the monochromator. The energy was calibrated by regularly measuring the spectrum of a reference metallic foil (first maximum of the derivative set at 7112 eV).
Observation mode
single spot
Experiment
Fe K edge XAS fluorescence of iron ferrous solution in hydrothermal conditions at 500bars and between 25 and 450°C
Date begin
2006-05-07
Release date
2018-01-31 23:51:01 UTC+0000
Version (Date)
#1 (2018-01-31 23:51:01 UTC+0000)
History
Date Mode Version Status Comments
2017-07-12 11:31:16 UTC+0000 first import #1 valid version First import
Analysis
raw averaged spectra
Quality flag
5