Fe K edge XAS transmission of bulk Niger CM chondrite: raw spectrum
- Title
- Fe K edge XAS transmission of bulk Niger CM chondrite: raw spectrum
- DOI
- 10.26302/SSHADE/EXPERIMENT_LB_20191211_001
- Data reference
- Garenne, Alexandre; Bonal, Lydie; Beck, Pierre; Proux, Olivier (2013): Fe K edge XAS transmission of bulk CM carbonaceous chondrites. SSHADE/GhoSST+FAME (OSUG Data Center). Dataset/Spectral Data. https://doi.org/10.26302/SSHADE/EXPERIMENT_LB_20191211_001
- Publications
- Database
- Experimentalists
- Experiment type
- laboratory measurement
- Type
- raw
- Intensity unit
- AU
- Comments
- 3 spectra were measured at different locations and averaged.
- Instrument
- X-ray Absorption Spectroscopy measured in transmission mode
- Sample holder
- simple holder
- Standard medium
- unknown
- Observation mode
- spectrum
- Spectral range type(s)
- hard X
- Valid spectral range(s)
-
Min - Max ($eV$) Sampling ($eV$) Resolution ($eV$) Position accuracy ($eV$) Absorption edge #1 7004.0 - 7385.0 0.365 $Fe$ (K: 7.112 $keV$) - Comments
- The resolution in the above table is the resolution given by the monochromator. The energy was calibrated by measuring the absorption edge of a reference: Fe metallic foil (first maximum of the derivative set at 7112 eV). The resolution of the spectrometer analyser was 0,365 eV (FWHM of the elastic peak).
Definition: incidence and emergence angles are positive with origin at nadir. Emergence angle in transmission is larger than 90° (=180°-i).
- Observation geometry
- direct
- Observation mode
- fixed angles
- Observation mode
- single spot
- Experiment
- Fe K edge XAS transmission of bulk CM carbonaceous chondrites
- Date begin
- 2013-09-02
- Release date
- 2020-01-13 11:07:42 UTC+0000
- Version (Date)
- #1 (2020-01-13 11:07:42 UTC+0000, Updated: 2020-01-13 11:07:42 UTC+0000)
- History
-
Date Mode Version Status Comments 2020-01-13 11:01:33 UTC+0000 first import #1 valid version
- Analysis
- averaged spectra
- Quality flag
- 5