Baseline corrected, normalized and average MIR transmission spectrum of matrix fragments of QUE97008 pressed on diamond window under vacuum and at temperature T = 100°C
- Title
- Baseline corrected, normalized and average MIR transmission spectrum of matrix fragments of QUE97008 pressed on diamond window under vacuum and at temperature T = 100°C
- DOI
- 10.26302/SSHADE/EXPERIMENT_LB_20221013_001
- Data reference
- Eschrig, Jolantha; Bonal, Lydie; Vacher, Lionel (2018): Baseline corrected, average and normalized MIR transmission spectra of matrix fragments of UOC chondrites, pressed on diamonds under vacuum and at several temperatures. SSHADE/GhoSST (OSUG Data Center). Dataset/Spectral Data. https://doi.org/10.26302/SSHADE/EXPERIMENT_LB_20221013_001
- Publications
- Database
- Experimentalists
- Experiment type
- laboratory measurement
- Type
- absorbance
- Comments
- individual spectra were first baseline-corrected, then normalized to 840 cm-1 and then averaged to obtain one spectrum]
- Instrument
- Brucker Vertex 70 + Hyperion 3000 – micro-transmission Mid-IR
- Sample holder
- The diamond windows were loaded into a cell, enabling temp. up to 300C under vacuum (from 10-4 mbar down to 10-7 mbar). Optical access is permitted from both sides of the cell through KBr windows, thus enabling measurements in transmission.
- Standard medium
- vacuum
- Observation mode
- spectrum
- Spectral range type(s)
- MIR
- Valid spectral range(s)
-
Min - Max ($cm^{-1}$) Sampling ($cm^{-1}$) Resolution ($cm^{-1}$) Position accuracy ($cm^{-1}$) Absorption edge #1 600.0 - 4000.0 1.928 4.0 0.05 - Scan number
- 200
- Observation mode
- single spot
- Spots number
- 1
- Objective type
- x15
- Pixels number
- 1 x 1
- Image size
- 40.0 x 40.0 ${\mu}m$
- Resolutions
- 3.0 ${\pm}$ 1.0 ${\mu}m$
- Comments
- the typical size of the spot on the sample was 40 microns x 40 microns
- Name
- QUE97008 matrix grains (UOC) heated at 100°C
- Primary constituent(s)
-
-
matrix QUE97008 heated at 100°C
Comments: matrix composed of minerals (hydrated and not hydrated) and organics
-
matrix QUE97008 heated at 100°C
- Experiment
- Baseline corrected, average and normalized MIR transmission spectra of matrix fragments of UOC chondrites, pressed on diamonds under vacuum and at several temperatures
- Date begin
- 2018-03-01
- Release date
- 2024-11-19 14:50:50 UTC+0000
- Version (Date)
- #1 (2024-11-19 14:50:50 UTC+0000, Updated: 2024-11-19 14:50:50 UTC+0000)
- History
-
Date Mode Version Status Comments 2022-10-13 16:33:02 UTC+0000 first import #1 valid version
- Analysis
- calibrated, baseline corrected, normalized and average spectrum
- Quality flag
- 3
- Validator(s)