- Database
- Experimentalists
- Date
- 2024-12-07
- Thickness
- 10.0 $\pm$ 5.0 ${\mu}m$
- Diameter
- 50.0 ${\mu}m$
- Substrate material
- microscope glass slide
- Comments
- manual selection under binocular of about 30 matrix fragments of approximate diameter of 50 microns
- Temperature
- 22.0 $\pm$ 2.0 $^{\circ}C$
- Temperature max
- 22.0 $\pm$ 2.0 $^{\circ}C$
- Comments
- sample prepared and stored after preparation, and data acquired under standard temperature and pressure conditions. The temperature may change during Raman data acquisition (laser irradiation), but it has not been quantified
- Type
- ambient air
- Fluid pressure
- 1.0 $\pm$ 0.1 $atm$
- Comments
- MATair_lab_wet
- Number
- 1
- Layers
-
- OC002 matrix fragments , 10.0 ${\mu}m$
- Title
- Preparation of the sample for Raman measurements
- Matters
- Sample
- OC002 matrix fragments (this sample)
- Processing steps
-
Step Chronology Date Type Process Changes #1 before layer formation mechanical Manual selection under optical binocular of about 30 matrix fragments of about 50 microns diameter. Matrix selected based on their black color and on their fine-grained texture #2 during layer formation mechanical Fragments pressed between two glass slides with a mechanical press matrix fragments crushed down to a thickness of about 10 microns