Spectrum

VisNIR reflectance spectrum of irradiated NWA 4968 pellet (He+, 3E16 ions/cm2)

Title
VisNIR reflectance spectrum of irradiated NWA 4968 pellet (He+, 3E16 ions/cm2)
DOI
10.26302/SSHADE/EXPERIMENT_ZED_20260116_01
Data reference
Rubino, Stefano (2022): $He^+$ irradiation of meterotic HED pellets probed by Vis-NIR spectroscopy. SSHADE/DAYSY (OSUG Data Center). Dataset/Spectral Data. https://doi.org/10.26302/SSHADE/EXPERIMENT_ZED_20260116_01
Publications
Database
Experimentalists
Experiment type
laboratory measurement
Type
bidirectional reflectance
Intensity unit
no unit
Comments
The Near-IR region of the spectrum (from 1 to 4 µm) was shifted to match the reflectance measured in the Visible region, using the reflectance in the Visible at 1 µm as anchor point.
Instrument
Maya2000 - microscopic reflection Visible-NIR
Standard medium
vacuum
Observation mode
spectrum
Spectral range type(s)
Vis
Valid spectral range(s)
Min - Max (${\mu}m$) Sampling (${\mu}m$) Resolution (${\mu}m$) Position accuracy (${\mu}m$) Absorption edge
#1 0.35995 - 1.1 0.0005 1.0
Observation geometry
bidirectional
Observation mode
fixed angles
Incidence angle
15.0°
Emergence angle
15.0°
Azimuth angle
0.0°
Phase angle
20.0°
Observation mode
single spot
Comments
Collection spot size of 4 mm in diameter
Instrument
Bruker Tensor - reflection Near-IR
Standard medium
vacuum
Observation mode
spectrum
Spectral range type(s)
NIR
Valid spectral range(s)
Min - Max (${\mu}m$) Sampling (${\mu}m$) Resolution (${\mu}m$) Position accuracy (${\mu}m$) Absorption edge
#1 1.0 - 4.0 0.0005 1.0
Observation geometry
bidirectional
Observation mode
fixed angles
Incidence angle
20.0°
Emergence angle
15.0°
Azimuth angle
0.0°
Phase angle
15.0°
Observation mode
single spot
Comments
Collection spot size of 4 mm in diameter
Name
NWA 4968 pellet
Comments
irradiated NWA 4968 pellet (He+, 3E16 ions/cm2)
Experiment
$He^+$ irradiation of meterotic HED pellets probed by Vis-NIR spectroscopy
Date begin
2022-01-01
Release date
2026-01-22 13:39:56+0000 UTC
Version (Date)
#1 (2026-01-22 13:39:56+0000 UTC, Updated: 2026-01-22 13:39:56+0000 UTC)
History
Date Mode Version Status Comments
2026-01-22 10:11:44+0000 UTC first import #1 valid version
Analysis
To calibrate the absolute reflectance of our measurement, we acquired reference spectra in the vacuum chamber using a Spectralon standard (99% Lambertian reflectance, Labsphere). An additional reference measurement was performed on InfraGold (Labsphere), which allowed the correction of minor NIR features present in the Spectralon spectrum.
Quality flag
4