- Database
- Experimentalists
- Date
- 2007-01-01
- Provider
- IPAG
- Thickness
- 1.0 $\pm$ 0.05 $mm$
- Diameter
- 30.0 $mm$
- Volume
- 700.0 $mm^3$
- Surface roughness
- low
- Substrate material
- aluminum anodized black
- Substrate comments
- diameter 30 mm, depth 1 mm
- Comments
- Mass of dry sample = 0.688g - used as martian analogue dust
- Temperature
- 243.1 $\pm$ 0.5 $K$
- Temperature max
- 443.0 $K$
- Time at Tmax
- 600.0 $min$
- Comments
- Sample temperature error is mostly due to possible vertical temperature gradient in the sample. Temperature reading accuracy and stability is 0.1K
- Type
- molecular gas
- Fluids
-
- $H_2O$ 100.0 %
- Fluid temperature
- 243.0 $\pm$ 5.0 $K$
- Fluid pressure
- 0.28 $\pm$ 0.0028 $mbar$
- Comments
- P/Ps = 0.757 +/- 0.075 - increasing H2O pressure - Fluid temperature error depicts estimated thermal gradient of gas in the cell
- Number
- 1
- Layers
-
- Volcanic tuff with H2O , 1.0 $mm$