- Database
- Experimentalists
- Date
- 2018-03-01
- Provider
- IPAG
- Parent sample
- LEW87248 matrix grains (UOC)
- Thickness
- 15.0 $\pm$ 5.0 ${\mu}m$
- Diameter
- 40.0 ${\mu}m$
- Substrate material
- diamond window
- Substrate comments
- diamond window of 3.5mm diameter
- Comments
- manual selection under binocular of about 10 matrix grains of approximate diameter between 30 and 50 microns
- Temperature
- 100.0 $\pm$ 5.0 $^{\circ}C$
- Temperature max
- 100.0 $\pm$ 5.0 $^{\circ}C$
- Time at Tmax
- 3600.0 $s$
- Type
- vacuum
- Fluid pressure
- 2.5e-06 $\pm$ 5.0e-07 $mbar$
- Comments
- sample put in a cell enabling acquisition under primary or secondary dynamic vacuum (from $10^{-4}$ mbar down to $10^{-7}$ mbar)
- Number
- 1
- Layers
-
- Layer #1 , 15.0 ${\mu}m$
- Title
- selection of the grains
- Samples
- Sample
- LEW87248 matrix grains (UOC) heated at 100°C (this sample)
- Processing steps
-
Step Chronology Date Type Process Changes #1 on parent sample 2018-03-01 thermal heating at 100°C under vacuum in an environmental cell partial reduction of the amount of adsorbed $H_2O$ - Comments
- heating in order to remove adsorbed water on the matrix grains