- Database
- Experimentalists
- Date
- 2023-01-01
- Provider
- IPAG
- Thickness
- 0.8 $\pm$ 0.1 $mm$
- Diameter
- 13.0 $mm$
- Mass
- 0.3055 $\pm$ 0.0012 $g$
- Substrate material
- sample holder in aluminum with a centered hole to hold the sample
- Comments
- KBr pellet of 13mm of diameter and 0.8mm thick
- Temperature
- 22.0 $\pm$ 2.0 $^{\circ}C$
- Temperature max
- 22.0 $\pm$ 2.0 $^{\circ}C$
- Type
- vacuum
- Fluid pressure
- 0.001 $mbar$
- Comments
- stored in a desiccator
- Number
- 1
- Layers
-
- MET01070-Orgueil mixture pellet , 0.8 $mm$
- Title
- Grinding of the MET01070 matter, Grinding of the Orgueil matter, mixing with KBr, pellet making
- Matters
- Sample
- MET01070_50+Orgueil_50 KBr pellet (this sample)
- Processing steps
-
Step Chronology Date Type Process Changes #1 before layer formation 2023-01-01 mechanical grinding bulk meteorite reduced to grains with size lower than 10 microns #2 before layer formation 2023-01-01 thermal 300 mg of commercial ultrapure KBr powder was heated under ambient air to 80°C overnight (~10h) removal of adsorbed/hydration water in KBr powder #3 before layer formation 2023-01-01 mixing homogeneous mixing 0.50 mg of MET01070 and 0.50 mg of Orgueil were weighed and mixed with 300 mg of dried commercial ultrapure KBr powder #4 during layer formation 2023-01-01 pressure pressure formation of a pellet of 13mm diameter and 0.8 mm thick under 400 bars of pressure