Sample
Name
C0052 fragments
Date
2022-09-01
Provider
JAXA
Thickness
10.0 ± 10.0 μm
Diameter
50.0 μm
Substrate material
synthetic type IIa diamond windows
Substrate comments
3 x 0.5 mm diamond windows
Comments
manual selection under binocular of about 10 fragments of approximate diameter of 30-50 microns
Temperature
22.0 ± 2.0 C
Temperature max
22.0 ± 2.0 C
Comments
HYB2 samples stored under N2
Type
ambient air
Fluid pressure
1.0 atm
Number
1
Layers
Title
selection and pressing of the grains

Precursors

Matters

Produced sample

Sample
C0052 fragments (this sample)
Processing steps
Step Chronology Date Type Process Changes
#1 before layer formation mechanical Manual selection of one or several fragment(s) of C0052 in a glove box filled with N2. The main C0050 particule was kept under N2 in a specific container and the selected fragments were then micro-manipulated under ambient air
#2 during layer formation mechanical Fragments pressed between two synthetic type IIa diamond windows with a mechanical press - ambient air fragments pressed between two diamond windows - unknown thickness